The test combination 2 offers three different high voltage output stages:
Category 1: Current limited
Category 2: 500 VA power
Category 3: 500 VA power and 100% duty cycle
Test voltages up to 7500 V AC and 7000 V DC can be realized on request. All models are already standardly designed for 5 kV AC and 7 kV DC tests. Likewise, an insulation test is included in all models as standard. All models automatically switch between the individual output stages. The test object does not have to be contacted!
General
Size: 19" / 6HE
Test type: manual / semi-automatic / fully automatic
Display: Menu guide with test assistants
Memory: up to 80 test programs
Start: on the back
RS232 interface: complete remote control of all device functions
High voltage test
Test voltage: 0-5 kV AC, 0-7 kV DC, electronic
Output power: 15 VA
Ramp function: 100 to 7000 V / s, rise and descent ramp separated
Short-circuit current: <3 mA
Test duration: 1 to 99 s
Punch indication: optical and acoustic
Current measurement: Apparent and active current measurement
Limits: Imin, Imax
Insulation test
Test voltage: 0-1 kV DC, electronic (up to 7 KV DC)
Test duration: 1 to 99 s
Limits: Rmin, Rmax
Measuring range: at least 1 GΩ
Protective conductor test
Test current: 5 to 30 A AC, electronically controlled
Method: Resistance, voltage drop VDE 0113, conductor cross-section
Test duration: 1 to 99 s
Limits: Rmin, Rmax
Measuring range: up to 300 mΩ
General
Size: 19" / 6HE
Test type: manual / semi-automatic / fully automatic
Display: Menu guide with test assistants
Memory: up to 80 test programs
Start: on the back
RS232 interface: complete remote control of all device functions
Duty cycle: approx. 50% ED
High voltage test
Test voltage: 0-5 kV AC, 0-7 kV DC, electronic
Output power: 500 VA
Ramp function: 100 to 7000 V / s, rise and descent ramp separated
Short-circuit current: at least 200 mA
Test duration: 1 to 99 s
Punch indication: optical and acoustic
Current measurement: Apparent and active current measurement
Limits: Imin, Imax, labsch
- Burnout function
Insulation test
Test voltage: 0-1 kV DC, electronic (up to 7 KV DC)
Test duration: 1 to 99 s
Limits: Rmin, Rmax
Measuring range: at least 1 GΩ
Protective conductor test
Test current: 5 to 30 A AC, electronically controlled
Method: Resistance, voltage drop VDE 0113, conductor cross-section
Test duration: 1 to 99 s
Limits: Rmin, Rmax
Measuring range: up to 300 mΩ
General
Size: 19" / 9HE
Test type: manual / semi-automatic / fully automatic
Display: Menu guide with test assistants
Memory: up to 80 test programs
Start: on the back
RS232 interface: complete remote control of all device functions
Duty cycle: 100% ED
High voltage test
Test voltage: 0-5 kV AC, 0-7 kV DC, electronic
Output power: 500 VA
Ramp function: 100 to 7000 V / s, rise and descent ramp separated
Short-circuit current: at least 200 mA
Test duration: 1 to 999 s
Punch indication: optical and acoustic
Current measurement: Apparent and active current measurement
Limits: Imin, Imax, labsch
- Burnout function
Insulation test
Test voltage: 0-1 kV DC, electronic (up to 7 KV DC)
Test duration: 1 to 999 s
Limits: Rmin, Rmax
Measuring range: at least 1 GΩ
Protective conductor test
Test current: 5 to 30 A AC, electronically controlled
Method: Resistance, voltage drop VDE 0113, conductor cross-section
Test duration: 1 to 999 s
Limits: Rmin, Rmax
Measuring range: up to 300 mΩ